Sensor
Type:
Thermal Differential, Dual RTD Sensors.
Process Connection:
Standard 0.75 inch MNPT.
Optionally 0.25 inch and larger MNPT and
various other process connections such as sanitary and flanges.
Insertion Length:
Standard 2.0 inch.
Optionally 0.5 inch or greater.
Operating Temperature Range:
Standard -1OO°F to 390°F
(-70°C to +200°C).
Medium Temperature to +572°F (+300°C).
High Temperature to +850°F (+458°C).
Materials of Construction:
Standard 316 Series Stainless Steel.
Optionally Hastelloy, Monel, Inconel and
other exotic materials.
Operating Pressure Range:
Standard to 3000 psia
(207 bar)
|
Electronics
Power:
Standard Field selectable 110VAC, 220 VAC, or 24 VDC at 3 watts
(No heater power required). Optionally 24 VAC
Operating Temperature Range:
Standard -40°F to+140°F
(-40°C to+60°C).
Optionally Remote electronics for use in higher temperature environments.
Outputs:
Independent primary relay DPDT and secondary relay SPDT, contacts
rated at 5 amp, 250 VAC with fail safe capability; built in time
delay 0 to 300 seconds for each channel.
Self-Test:
Integral and automatic during power up.
Failure Alarm Option:
Continuous monitoring circuit to alarm should a failure condition
of any sensor, component, wiring, or power occur. (Uses one or two
channels of the VS5100)
Enclosure:
Explosion proof; NEMA 3, 4, 7, and 9:CSA, FM, UL, CENELEC, and EECS
approved.
|
Instrument
Operating Range:
Flow 0.01 to 5.0 fps in liquids and 0.1 to 500 fps in gases. Level
change as small as .-3 inch. Temperature -70°C to +458°C +/- 1°C.
Response Time:
Media dependent 0.5 to 10 seconds.
Approvals:
FM and CSA
|